References

Dorn Spinal Therapy

Spine Healing Therapy

Get Instant Access

Adams, G.R., Harris, R.T., et al. (1993). Mapping of electrical muscle stimulation using MRI. J Appl Physiol, 74(2), 532-537.

Alon, G. (1985). High voltage stimulation. Effects of electrode size on basic excitatory responses. Phys Ther, 65(6), 890-895.

Alon, G. (2003). Training dosage and timing of electrical stimulation may be the key for maximizing the effects of NMES in neuro-rehabilitation. Adv Physical Rehabil Med, N. Soroker and H. Ring, Monduzzi Editore, 441-447.

Alon, G., Allin, J., et al. (1983). Optimization of pulse duration and pulse charge during transcutaneous electrical nerve stimulation. Aust JPhysiother, 29, 195-201.

Alon, G., Dar, A., et al. (1998). Efficacy of a hybrid upper limb neuromuscular electrical stimulation system in lessenning selected impairments and dysfunctions consequent to cerebral damage. J Neuro Rehabil, 12, 73-80.

Alon, G., Kantor, G., et al. (1994). Effects of electrode size on basic excitatory responses and on selected stimulus parameters. J Orthop Sports Phys Ther, 20(1), 29-35.

Alon, G., Kantor, G., et al. (1996). The effect of three types of surface electrodes on threshold excitation of human motor nerve. J Clin Electrophysiol, 8, 2-8.

Alon, G. and McBride, K. (2003). Persons with C5 or C6 tetraple-gia achieve selected functional gains using a neuroprosthe-sis. Arch Phys Med Rehabil, 84(1), 119-124.

Alon, G., McBride, S., et al. (2002). Improving selected hand functions using upper extremity noninvasive neuropros-thesis in persons with chronic stroke. J Stroke Cerebrovascul Dis, 11, 99-106.

Alon, G. and Ring, H. (2003). Gait and hand function enhancement following training with a multi-segment hybrid-orthosis stimulation system in stroke patients. J Stroke Cerebrovascul Dis, 12(5), 209-216.

Alon, G., Sunnerhagen, K.S., et al. (2003). A home-based, self-administered stimulation program to improve selected hand functions of chronic stroke. Neurorehabilitation, 18(3), 215-225.

Baker, L.L., Bowman, B.R., et al. (1988). Effects of waveform on comfort during neuromuscular electrical stimulation. Clin Orthop, (233), 75-85.

Baker, L.L., Benton, L.A., et al. (1993). Neuromuscular Electrical Stimulation: A Practical Guide. Rancho Los Amigos Medical Center, Downey, California.

Bennie, S.D., Petrofsky, J.S., et al. (2002). Toward the optimal waveform for electrical stimulation of human muscle. Eur J Appl Physiol, 88(1-2), 13-19.

Berner, Y.N., Lif Kimchi, O., Spokoiny, V, Finkeltov, B. (2004). The effect of electric stimulation treatment of the functional rehabilitation of acute geriatric patients with stroke -a preliminary study. Arch Gerontol Geriatr, 39(2): 125-132.

Billian, C. and Gorman, P.H. (1992). Upper extremity applications of functional neuromuscular stimulation. Assist Technol, 4(1), 31-39.

Binder-Macleod, S.A. and Guerin, T. (1990). Preservation of force output through progressive reduction of stimulation frequency in human quadriceps femoris muscle. Phys Ther, 70(10), 619-625.

Binder-Macleod, S.A. and Lee, S.C. (1996). Catchlike property of human muscle during isovelocity movements. J Appl Physiol, 80(6), 2051-2059.

Brindley, G.S. (1995). The first 500 sacral anterior root stimulators: implant failures and their repair. Paraplegia, 33(1), 5-9.

Brindley, G.S. and Rushton, D.N. (1990). Long-term follow-up of patients with sacral anterior root stimulator implants. Paraplegia, 28(8), 469-475.

Burridge, J., Taylor, P., et al. (1997a). Experience of clinical use of the Odstock dropped foot stimulator. Artif Organs, 21(3), 254-260.

Burridge, J.H., Taylor, P.N., et al. (1997b). The effects of common peroneal stimulation on the effort and speed of walking: a randomized controlled trial with chronic hemiplegic patients. Clin Rehabil, 11(3), 201-210.

Cauraugh, J.H. and Kim, S. (2002). Two coupled motor recovery protocols are better than one: electromyogram-triggered neuromuscular stimulation and bilateral movements. Stroke, 33(6), 1589-1594.

Cauraugh, J.H. and Kim, S. (2003a). Progress toward motor recovery with active neuromuscular stimulation: muscle activation pattern evidence after a stroke. J Neurol Sci, 207(1-2), 25-29.

Cauraugh, J.H. and Kim, S.B. (2003b). Chronic stroke motor recovery: duration of active neuromuscular stimulation. J Neurol Sci, 215(1-2), 13-19.

Cauraugh, J.H. and Kim, S.B. (2003c). Stroke motor recovery: active neuromuscular stimulation and repetitive practice schedules. J Neurol Neurosurg Psychiatr, 74(11), 1562-1566.

Cauraugh, J., Light, K., et al. (2000). Chronic motor dysfunction after stroke: recovering wrist and finger extension by elec-tromyography-triggered neuromuscular stimulation. Stroke, 31(6), 1360-1364.

Cestari, I.A., Marques, E., et al. (1995). Effects of muscle length, frequency of stimulation, and fatigue on the isometric tension in canine latissimus dorsi. Artif Organs, 19(3), 217-221.

Chae, J., Bethoux, F., et al. (1998). Neuromuscular stimulation for upper extremity motor and functional recovery in acute hemiplegia. Stroke, 29(5), 975-979.

Chantraine, A., Baribeault, A., et al. (1999). Shoulder pain and dysfunction in hemiplegia: effects of functional electrical stimulation. Arch Phys Med Rehabil, 80(3), 328-331.

Crago, P.E., Peckham, P.H., et al. (1974). The choice of pulse duration for chronic electrical stimulation via surface, nerve, and intramuscular electrodes. Ann Biomed Eng, 2(3), 252-264.

Crago, P.E., Nakai, R.J., et al. (1991). Feedback regulation of hand grasp opening and contact force during stimulation of paralyzed muscle. IEEE TransBiomedEng, 38(1), 17-28.

Creasey, G. (1999). Restoration of bladder, bowel, and sexual function. Top Spinal Cord Inj Rehabil, 5(1), 21-32.

Creasey, G.H., Kilgore, K.L., et al. (2000). Reduction of costs of disability using neuroprostheses. Assist Technol, 12(1), 67-75.

DiMarco, A.F. (2001). Neural prostheses in the respiratory system. J Rehabil Res Dev, 38(6), 601-607.

Faghri, P.D., Rodgers, M.M., et al. (1994). The effects of functional electrical stimulation on shoulder subluxation, arm function recovery, and shoulder pain in hemiplegic stroke patients. Arch Phys Med Rehabil, 75(1), 73-79.

Francisco, G., Chae, J., et al. (1998). Electromyogram-triggered neuromuscular stimulation for improving the arm function of acute stroke survivors: a randomized pilot study? Arch Phys Med Rehabil, 79(5), 570-575.

Friedli, W.G. and Meyer, M. (1984). Strength-duration curve: a measure for assessing sensory deficit in peripheral neuropathy. J Neurol Neurosurg Psychiatr, 47(2), 184-189.

Frijns, J.H., Mooij, J., et al. (1994). A quantitative approach to modeling mammalian myelinated nerve fibers for electrical prosthesis design. IEEE Trans Biomed Eng, 41(6), 556-566.

Galea, V. (2001). Electrical characteristics of human ankle dorsi-and plantar-flexor muscles. Comparative responses during fatiguing stimulation and recovery. Eur J Appl Physiol, 85(1-2), 130-140.

Glaser, R. (1991). Physiology of functional electrical stimulation-induced exercise: basic science perspective. J Neuro Rehab, 5(1-2), 49-61.

Glenn, W.W. and Phelps, M.L. (1985). Diaphragm pacing by electrical stimulation of the phrenic nerve. Neurosurgery, 17(6), 974-984.

Gold, M.R. and Shorofsky, S.R. (1997). Strength-duration relationship for human transvenous defibrillation. Circulation, 96(10), 3517-3520.

Gracanin, F. and Trnkoczy, A. (1975). Optimal stimulus parameters for minimum pain in the chronic stimulation of innervated muscle. Arch Phys Med Rehabil, 56(6), 243-249.

Graupe, D. and Kohn, K.H. (1998). Functional neuromuscular stimulator for short-distance ambulation by certain thoracic-level spinal-cord-injured paraplegics. Surg Neurol, 50(3), 202-207.

Han, B.S., Jang, S.H., et al. (2003). Functional magnetic resonance image finding of cortical activation by neuromuscu-lar electrical stimulation on wrist extensor muscles. Am J Phys Med Rehabil, 82(1), 17-20.

Hasan, S.T., Robson, W.A., et al. (1996). Transcutaneous electrical nerve stimulation and temporary S3 neuromodulation in idiopathic detrusor instability. J Urol, 155(6), 2005-2011.

Hazlewood, M.E., Brown, J.K., et al. (1994). The use of therapeutic electrical stimulation in the treatment of hemiplegic cerebral palsy. Dev Med Child Neurol, 36(8), 661-673.

Henkin, Y., Kaplan-Neeman, R., et al. (2003). Changes over time in electrical stimulation levels and electrode impedance values in children using the Nucleus 24M cochlear implant. Int J Pediatr Otorhinolaryngol, 67(8), 873-880.

Iggo, A. (1978). The physiological interpretation of electrical stimulation of the nervous system. Electroencephalogr Clin Neurophysiol Suppl, 34, 335-341.

Jjzerman, M.J., in 't Groen, F.A., Klatte, M.A.P., Snock, O.J., Vorsteveld, J.H.C., Nathan, R.H., Hermens, H.J. (1996). The NESS Handmaster orthosis: restoration of hand function in C5 and stroke patients by means of electrical stimulation. J Rehabil Sci, 9, 86-89.

Johnson, M.W., Peckham, P.H., et al. (1999). Implantable transducer for two-degree of freedom joint angle sensing. IEEE Trans Rehabil Eng, 7(3), 349-359.

Kantor, G., Alon, G., et al. (1994). The effects of selected stimulus waveforms on pulse and phase characteristics at sensory and motor thresholds. Phys Ther, 74(10), 951-962.

Keith, M.W., Kilgore, K.L., et al. (1996). Tendon transfers and functional electrical stimulation for restoration of hand function in spinal cord injury. J Hand Surg [Am], 21(1), 89-99.

Kern, H., Hofer, C., et al. (1999). Standing up with denervated muscles in humans using functional electrical stimulation. Artif Organ, 23(5), 447-452.

Kern, H., Hofer, C., et al. (2002). Denervated muscles in humans: limitations and problems of currently used functional electrical stimulation training protocols. Artif Organ, 26(3), 216-218.

Kilgore, K.L., Peckham, P.H., et al. (1997). An implanted upper-extremity neuro prosthesis. Follow-up of five patients. J Bone Joint Surg Am, 79(4), 533-541.

Kimberley, T.J., Lewis, S.M., et al. (2004). Electrical stimulation driving functional improvements and cortical changes in subjects with stroke. Exp Brain Res, 154(4), 450-460.

Knaflitz, M., Merletti, R., et al. (1990). Inference of motor unit recruitment order in voluntary and electrically elicited contractions. JAppl Physiol, 68(4), 1657-1667.

Lauer, R.T., Kilgore, K.L., et al. (1999). The function of the finger intrinsic muscles in response to electrical stimulation. IEEE Trans Rehabil Eng, 7(1), 19-26.

Laufer, Y., Ries, J.D., et al. (2001). Quadriceps femoris muscle torques and fatigue generated by neuromuscular electrical stimulation with three different waveforms. Phys Ther, 81(7), 1307-1316.

Linn, S.L., Granat, M.H., et al. (1999). Prevention of shoulder subluxation after stroke with electrical stimulation. Stroke, 30(5), 963-968.

MacDonagh, R.P., Sun, W.M., et al. (1990). Control of defecation in patients with spinal injuries by stimulation of sacral anterior nerve roots. Br Med J, 300(6738), 1494-1497.

MacLean, I.C. and Mattioni, T.A. (1981). Phrenic nerve conduction studies: a new technique and its application in quadriplegic patients. Arch Phys Med Rehabil, 62(2), 70-73.

Malezic, M., Bogataj, U., et al. (1987). Evaluation of gait with multichannel electrical stimulation. Orthopedics, 10(5), 769-772.

Memberg, W., Peckham P.H., Thrope, G.B., Keith, M.W., Kicher T.P. (1993). An analysis of the reliability of percutaneous intramuscular electrodes in upper extremity FNS applications. IEEE Trans Rehab Eng, 1(2), 126-132.

Mohr, T., Podenphant, J., et al. (1997). Increased bone mineral density after prolonged electrically induced cycle training of paralyzed limbs in spinal cord injured man. Calcif Tissue Int, 61(1), 22-25.

Mortimer, J. (1981). Motor Prostheses. In: Handbook of Physiology - The Nervous System II, Motor Control (ed. Brooks, VB.), American Physiology Society, Bethesda, MD, pp. 158-187.

Muellbacher, W., Richards, C., Ziemann, U., Wittenberg, G., Weltz, D., Boroojerdi B., et al. (2002). Improving hand function in chronic stroke. Arch Neurol, 59(8), 1278-1282.

Mulcahey, M.J., Smith, B.T., et al. (1999). Evaluation of the lower motor neuron integrity of upper extremity muscles in high level spinal cord injury. Spinal Cord, 37(8), 585-591.

Munsat, T.L., McNeal, D., et al. (1976). Effects of nerve stimulation on human muscle. Arch Neurol, 33(9), 608-617.

Naaman, S.C., Stein, R.B., et al. (2000). Minimizing discomfort with surface neuromuscular stimulation. Neurorehabil Neural Repair, 14(3), 223-228.

Nathan, R.H. and Ohry, A. (1990). Upper limb functions regained in quadriplegia: a hybrid computerized neuromuscular stimulation system. Arch Phys Med Rehabil, 71(6), 415-421.

Oda, T., Glenn, W.W., et al. (1981). Evaluation of electrical parameters for diaphragm pacing: an experimental study. J Surg Res, 30(2), 142-153.

Ohl, D. (1993). Electroejaculation. Urol Clin North Am, 20(1), 181-188.

Pandyan, A.D., Granat, M.H., et al. (1997). Effects of electrical stimulation on flexion contractures in the hemiplegic wrist. Clin Rehabil, 11(2), 123-130.

Panescu, D., Webster, J.G., et al. (1994a). Modeling current density distributions during transcutaneous cardiac pacing. IEEE Trans Biomed Eng,41(6), 549-555.

Panescu, D., Webster, J.G., et al. (1994b). A nonlinear finite element model of the electrode-electrolyte-skin system. IEEE Trans Biomed Eng, 41(7), 681-687.

Peckham, P.H. (1987). Functional electrical stimulation: current status and future prospects of applications to the neuromus-cular system in spinal cord injury. Paraplegia, 25(3), 279-288.

Peckham, P.H. and Creasey, G.H. (1992). Neural prostheses: clinical applications of functional electrical stimulation in spinal cord injury. Paraplegia, 30(2), 96-101.

Peckham, P.H., Keith, M.W., et al. (2001). Efficacy of an implanted neuroprosthesis for restoring hand grasp in tetraplegia: a multicenter study. Arch Phys Med Rehabil, 82(10), 1380-1388.

Popovic, M.B., Popovic, D.B., et al. (2003). Clinical evaluation of functional electrical therapy in acute hemiplegic subjects. JRehabilRes Dev, 40(5), 443-454.

Powell, J., Pandyan, A.D., et al. (1999). Electrical stimulation of wrist extensors in poststroke hemiplegia. Stroke, 30(7), 1384-1389.

Ragnarsson, K., Pollack, S.F. and Twist, D. (1991). Lower limb endurance exercise after spinal cord injury: implications for health and functional ambulation. J. Neuro Rehab, 5(1-2), 37-48.

Ring, H. and Rosenthal, N. (2005). Controlled study of neuro-prosthetic functional electrical stimulation in sub-acute post-stroke rehabilitation. J Rehabil Med, 37(1), 32-6.

Rollman, G.B. (1975). Behavioral assessment of peripheral nerve function. Neurology, 25(4), 339-342.

Russ, D.W. and Binder-Macleod, S.A. (1999). Variable-frequency trains offset low-frequency fatigue in human skeletal muscle. Muscle Nerve, 22(7), 874-882.

Smith, L.E. (1990). Restoration of volitional limb movement of hemiplegics following patterned functional electrical stimulation. Percept Mot Skilk, 71(3 Part 1), 851-861.

Smith, G.V., Alon, G., Roys S.R. and Gullapalli, R.P. (2003). Functional MRI determination of a dose-response relationship to lower extremity neuromuscular electrical stimulation in healthy subjects. Exp Brain Res, 150(1), 33-9.

Solomonow, M., Reisin, E., et al. (1997). Reciprocating gait orthosis powered with electrical muscle stimulation (RGO II). Part II: Medical evaluation of 70 paraplegic patients. Orthopedics, 20(5), 411-418.

Taylor, P.N., Burridge, J.H., et al. (1999). Clinical use of the Odstock dropped foot stimulator: its effect on the speed and effort of walking. Arch Phys Med Rehabil, 80(12), 1577-1583.

Triolo, R.J., Bieri, C., et al. (1996). Implanted functional neuromuscular stimulation systems for individuals with cervical spinal cord injuries: clinical case reports. Arch Phys Med Rehabil, 77(11), 1119-1128.

Van Kerrebroeck, P.E., Koldewijn, E.L., et al. (1993). Worldwide experience with the Finetech-Brindley sacral anterior root stimulator. Neurourol Urodyn, 12(5), 497-503.

Vanderthommen, M., Depresseux, J.C., et al. (2000). Spatial distribution of blood flow in electrically stimulated human muscle: a positron emission tomography study. Muscle Nerve, 23(4), 482-489.

Wang, R.Y., Chan, R.C., et al. (2000). Functional electrical stimulation on chronic and acute hemiplegic shoulder subluxation. Am J Phys Med Rehabil, 79(4), 385-390; quiz 391-394.

Weingarden, H.P., Zeilig, G., et al. (1998). Hybrid functional electrical stimulation orthosis system for the upper limb: effects on spasticity in chronic stable hemiplegia. Am J Phys Med Rehabil, 77(4), 276-281.

Wesselink, W.A., Holsheimer, J., et al. (1999). A model of the electrical behaviour of myelinated sensory nerve fibres based on human data. Med Biol Eng Comput, 37(2), 228-235.

Yan, T., Hui-Chan, C.W. and Li, L.S. (2005). Functional electrical stimulation improves motor recovery of the lower extremity and walking ability of subjects with first acute stroke: a randomized placebo-controlled trial. Stroke, 36(1), 80-5.

Was this article helpful?

0 0
Peripheral Neuropathy Natural Treatment Options

Peripheral Neuropathy Natural Treatment Options

This guide will help millions of people understand this condition so that they can take control of their lives and make informed decisions. The ebook covers information on a vast number of different types of neuropathy. In addition, it will be a useful resource for their families, caregivers, and health care providers.

Get My Free Ebook


Post a comment